期刊文章详细信息
基于LIBS技术的钢丝表调液Zn元素快速检测分析
Rapid detection and analysis of Zn element in steel wire surface adjustment liquid based on LIBS technology
文献类型:期刊文章
SHI Chen;MA Mingjun;FANG Li;ZHAO Nanjing;YIN Gaofang;CHEN Fuqiang;ZHANG Xiaoling(Institute of Environmental Physics and Technology,Institutes of Physical Science and Information Technology,Anhui University,Hefei 230601,China;Key Laboratory of Environmental Optics and Technology of Chinese Academy of Sciences,Anhui Institute of Optics and Precision Machinery,Hefei Institute of Physical Science,Chinese Academy of Sciences,Hefei 230031,China;Anhui Province Environment Key Laboratory of Optical Monitoring Technology,Chinese Academy of Sciences,Hefei 230031,China;School of Environmental Science and Optoelectronics Technology,University of Science and Technology of China,Hefei 230026,China)
机构地区:[1]安徽大学物质科学与信息技术研究院环境物理与技术研究所,合肥230601 [2]中国科学院合肥物质科学研究院安徽光学精密机械研究所中国科学院环境光学与技术重点实验室,合肥230031 [3]中国科学院安徽省环境光学监测技术重点实验室,合肥230031 [4]中国科学技术大学环境科学与光电技术学院,合肥230026
基 金:国家自然科学基金资助项目(62001453);中国科学院合肥物质科学研究院院长基金资助项目(YZJJ2024QN03)。
年 份:2025
卷 号:49
期 号:2
起止页码:175-179
语 种:中文
收录情况:BDHX、BDHX2023、核心刊
摘 要:为了实现钢丝表调液在线快速检测,采用滤纸富集钢丝表调液,验证富集方式的可行性;在此基础上研究了pH值对激光诱导击穿光谱(LIBS)技术检测结果的影响,并通过匹配标准样pH值分别建立定标曲线,反演某钢丝厂7种表调液中的Zn元素,进行了理论分析和实验验证。结果表明,Zn含量相同时,随着pH值变化,其LIBS光谱强度有显著差异;不同种类钢丝表调液pH值覆盖-0.91~8.95,针对不同pH值样品,其相关系数均达0.98以上,7种表调液LIBS技术检测与电感耦合等离子体质谱法检测结果之间平均相对误差为-13.09%;用LIBS技术结合pH值匹配建立定标曲线,可实现钢丝表调液中Zn元素快速准确测量。该研究为LIBS技术应用到钢丝生产过程中表调液关键元素的在线检测提供了方法基础。
关 键 词:光谱学 快速检测 激光诱导击穿光谱 重金属 钢丝表调液
分 类 号:O657.38]