期刊文章详细信息
内镜下高频电刀行结肠息肉切除的有效性及安全性
Efficacy and safety of endoscopic colorectal polypectomy with high-frequency electrotome
文献类型:期刊文章
Shen Caifei;Zhao Kui;Wang Liming;Wu Xiaoyu;Jiang Haiyang;Zhao Yaqin;Ma Shuang;Sun Xiaobin(Department of Gastroenterology,The Third People′s Hospital of Chengdu,Chengdu 610031,China;Department of Gastroenterology,The First Affiliated Hospital of Chengdu Medical College,Chengdu 610500,China;Digestive Endoscopy Center,Sichuan Mianyang Hospital of Traditional Chinese Medicine,Mianyang 621000,China;Department of Gastroenterology,The Fourth People′s Hospital of Ziyang City,Ziyang 641300,China;Department of Gastroenterology,Santai County Hospital of Traditional Chinese Medicine,Mianyang 621100,China;The First Department of Internal Medicine,Pengshan District People′s Hospital of Meishan City,Meishan 620860,China)
机构地区:[1]成都市第三人民医院消化内科,610031 [2]成都医学院第一附属医院消化内科,610500 [3]四川省綿阳市中医医院消化内镜中心,621000 [4]四川省资阳市第四人民医院消化内科,641300 [5]四川省三台县中医院消化内科,绵阳市621100 [6]四川省眉山市彭山区人民医院内一科,620860
年 份:2021
卷 号:38
期 号:6
起止页码:475-478
语 种:中文
收录情况:CSCD、CSCD_E2021_2022、JST、ZGKJHX、普通刊
摘 要:通过采集2020年6月—2020年9月四川地区6家医院使用高频电刀行内镜下结肠息肉切除术的643例资料,包括息肉完整切除、术后迟发性出血、穿孔等情况,分析高频电刀行结肠息肉切除的有效性及安全性。结果显示患者中发生迟发性出血18例(2.80%),术后穿孔1例(0.16%)。1828枚息肉病灶均得到完整切除(100.0%)。单因素分析显示直径≥10 mm、息肉形态为长蒂或侧向发育型肿瘤、病理为腺瘤性息肉、采取内镜黏膜切除术切除、采取混切1电凝模式是高频电刀内镜下结肠息肉切除术后发生迟发性出血的影响因素(P<0.05)。多因素Logistic回归分析显示息肉直径≥10 mm(P=0.001,OR=3.575,95%CI:1.175~9.955)、息肉形态为长蒂或侧向发育型肿瘤(P=0.004,OR=2.981,95%CI:1.233~14.858)是迟发性出血发生的独立危险因素。提示内镜下采用高频电刀行结肠息肉切除具有较高的有效性及安全性,但对于息肉直径≥10 mm、息肉形态为长蒂或侧向发育型肿瘤须警惕术后迟发性出血的发生。
关 键 词:结肠息肉 手术后出血 危险因素
分 类 号:R735.35]
参考文献:
正在载入数据...
二级参考文献:
正在载入数据...
耦合文献:
正在载入数据...
引证文献:
正在载入数据...
二级引证文献:
正在载入数据...
同被引文献:
正在载入数据...