期刊文章详细信息
卤代羟基烷类吸入用麻醉剂对血液中乙醇含量检测的影响
Influence of Halogenated Hydroxyl-Alkanes Inhalation Anesthetic on the Determi⁃nation of Ethanol Content in Blood
文献类型:期刊文章
XIE Bing;YAN Wen-jing;MENG Xian-yue;MIAO Xin-gang;YU Feng;DONG Mei;SHI Yan;XIANG Ping;MA Chun-ling;WEN Di(Collaborative Innovation Center of Forensic Medical Molecular Identification,Hebei Key Laboratory of Fo-rensic Medicine,College of Forensic Medicine,Hebei Medical University,Shijiazhuang 050017,China;Huang-hua Forensic Identification Center,Huanghua 061100,Hebei Province,China;Shijiazhuang Public Trans-portation Administration Bureau,Shijiazhuang 050091,China;Shanghai Key Laboratory of Forensic Medi-cine,Key Laboratory of Forensic Science,Ministry of Justice,Shanghai Forensic Service Platform,Academy of Forensic Science,Shanghai 200063,China)
机构地区:[1]河北医科大学法医学院河北省法医学重点实验室河北省法医分子鉴定协同创新中心,河北石家庄050017 [2]河北黄骅法医鉴定中心,河北黄骅061100 [3]石家庄市公安局交通管理局,河北石家庄050091 [4]司法鉴定科学研究院上海市法医学重点实验室司法部司法鉴定重点实验室上海市司法鉴定专业技术服务平台,上海200063
基 金:国家重点研发计划资助项目(2018YFC0807204,2016YFC0800704)。
年 份:2020
卷 号:36
期 号:5
起止页码:682-687
语 种:中文
收录情况:CAS、CSCD、CSCD_E2019_2020、EMBASE、IC、JST、PUBMED、RCCSE、SCOPUS、ZGKJHX、普通刊
摘 要:目的研究血液中的卤代羟基烷类吸入用全身麻醉剂对血液中乙醇含量检测的影响。方法利用顶空气相色谱双柱确认检测方法对卤代羟基烷类进行分析,观察其在KB-BAC1/KB-BAC2和J&W DBALC1/DB-ALC2气相色谱柱条件下对顶空气相色谱法检测血液中乙醇含量的影响。结果J&W DBALC1/DB-ALC2气相色谱柱中,七氟烷、恩氟烷分别与乙醇和叔丁醇的保留时间相近,对血液中乙醇含量的检测存在干扰;仅J&W DB-ALC1气相色谱柱可分离七氟烷和乙醇成分,以排除其对血液中乙醇含量检测的影响。在KB-BAC1/KB-BAC2气相色谱柱中,七氟烷、异氟烷与乙醇的保留时间相近,尤其是七氟烷与乙醇的保留时间基本一致,对血液中乙醇含量检测存在明显干扰。结论卤代羟基烷类对顶空气相色谱法检测血液中乙醇含量存在干扰,选择适当的色谱柱进行双柱确认检测可有效予以甄别。
关 键 词:法医毒理学 卤代羟基烷 麻醉药,吸入 乙醇 顶空气相色谱法 血液
分 类 号:DF795.1[法医学类]
参考文献:
正在载入数据...
二级参考文献:
正在载入数据...
耦合文献:
正在载入数据...
引证文献:
正在载入数据...
二级引证文献:
正在载入数据...
同被引文献:
正在载入数据...