登录    注册    忘记密码

期刊文章详细信息

基于改进负载潮流熵指标准确辨识电网脆性支路的方法  ( EI收录)  

Accurate Identification Method of Brittle Branches in Power Grid Based on Improved Load Flow Entropy Indexes

  

文献类型:期刊文章

作  者:李美成[1] 梅文明[1,2] 刘永强[3] 张凌康[4] 宋墩文[2] 赵充[1]

LI Meicheng;MEI Wenming;LIU Yongqiang;ZHANG Lingkang;SONG Dunwen;ZHAO Chong(State Key Laboratory for Alternate Electrical Power System With Renewable Energy Sources (North China Electric Power University),Changping District,Beijing 102206,China;State Grid Shanxi Electric Power Corporation,Lüliang Power Supply Company,Lvliang 033000,Shanxi Province,China;State Grid Gangsu Electric Power Corporation,Jiuquan Power Supply Company,Jiuquan 735000,Gansu Province,China;State Key Laboratory of Operation and Control of Renewable Energy & Storage Systems (China Electric Power Research Institute),Haidian District,Beijing 100192,China)

机构地区:[1]新能源电力系统国家重点实验室(华北电力大学),北京市昌平区102206 [2]新能源与储能运行控制国家重点实验室(中国电力科学研究院有限公司),北京市海淀区100192 [3]国网山西省电力公司吕梁供电公司,山西省吕梁市033000 [4]国网甘肃省电力公司酒泉供电公司,甘肃省酒泉市735000

出  处:《电网技术》

基  金:国家电网公司科技项目资助(SGSCLL00FCJS1800294)~~

年  份:2019

卷  号:43

期  号:3

起止页码:1026-1033

语  种:中文

收录情况:AJ、BDHX、BDHX2017、CSA、CSA-PROQEUST、CSCD、CSCD2019_2020、EI、IC、JST、RCCSE、SCOPUS、ZGKJHX、核心刊

摘  要:电力系统关键环节定位是电网安全分析的核心问题。针对基于潮流状态识别脆性支路只考虑系统静态特性,存在忽略系统运行极限及元件本身特性影响的不足,以及基于电网复杂拓扑结构分析辨识脆性支路时忽略电压运行状态影响,容易引起漏选的缺陷,提出一套改进负载潮流熵权指标准确辨识电网脆性支路的方法,由2阶段3类排序筛选构成,初筛阶段提出负载潮流熵和支路开断熵测度两指标,能准确评估电网稳态时支路不稳定运行特征,以及电网受扰后系统维持稳定运行的趋势。深筛阶段提出含调节因子的双测度熵和加权综合熵指标,满足电网设计或运行等不同场景对辨识脆性支路的需求。针对所提辨识方法,选经典IEEE10机39节点算例,并与其他方法开展对比实验,表明所提方法能更全面、更准确辨识电网脆性支路的优点。

关 键 词:脆性支路辨识  负载潮流熵  支路开断熵  加权综合熵  电网安全运行

分 类 号:TM721]